On the exterior the pan flashing should lap over the deck or masonry flashing below.
Door head flashing detail.
A self adhered head flashing strip should be installed across the top of the doorway and over the drip cap vertical leg.
Angled metal drip cap flashing material extending over the door head trim and returning at the ends should than be installed.
Whatever material is used all pans should have a dam on the ends and along the inside edge.
It is recommended for peace of mind against water intrusion and mold.
Solder head flashing at the ends to make watertight.
Flashing installed at the base of the rough opening to allow water which may enter through or around the window door to drain out.
Figure 3 27 above pan flashing and threshold details below an entry door.
Figure 1 garage door head detail with masonry veneer cladding and infill panel over the door.
Figure 3 garage door head detail with bevel back horizontal weatherboard cladding over a cavity.
Window and door flashing guide this collection of articles and videos will help you find the materials and construction details you need for a leak free installation of doors windows siding and more.
Jamb flashing and head flashing.
When properly installed vycor plus flashing tape reduces the risk of mold and rot development and contributes to energy efficiency.
Head flashings are used to direct water away from openings such as windows and doors.
The head flashing strip should extend a 6 inch minimum over the top of the side jamb flashing.
Sill or pan flashing.
Flashing installed at the sides jambs and top head of the window door.
White pvc the suresill 4 9 16 in.
White pvc sloped sill pan for door and window installation and flashing complete pack the suresill 4 9 16 in.
Continue to 2 1 sealant joint design hammer hand s best practices manual is covered by a creative commons license that allows for redistribution commercial and non commercial as long as content is passed along unchanged and in whole with credit to hammer hand.
The kick out flashing directs water away from the adjoining wall and ensures that the step flashing is not concentrating water on the surface of that wall.
Figure 2 garage door head detail with direct fixed bevel back horizontal weatherboard cladding.
Wall underlay turned in to door opening with flexible flashing tape to corners flexible flashing tape to head flashing upstand or additional layer of underlay cavity closure head flashing with 15 slope and stop ends 35 mm minimum flashing.
Water resistive arrier wr.
Vycor plus 4 in.
Figure 3 26 above flashing details above and below an exterior door.
Head flashings should be installed with a positive slope to the exterior.
Figure 3 garage door head detail with bevel back horizontal weatherboard cladding over a cavity.
Roll fully adhered flashing tape 25 sq.